Power Supply Alarm
This alarm is applicable only to MP-1288, Mediant 1000, Mediant 2600, Mediant 3100, Mediant 4000, and Mediant 9000.
acPowerSupplyAlarm
Alarm |
acPowerSupplyAlarm |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.30 |
|||||||||||
Description |
The alarm is sent when a fault occurs in one of the Power Supply modules or a Power Supply module is not installed in the chassis or not installed properly. Note:
|
|||||||||||
Default Severity |
Critical |
|||||||||||
Source Varbind Text |
Chassis#0/PowerSupply#<m>, where m is the power supply’s slot number |
|||||||||||
Event Type |
equipmentAlarm |
|||||||||||
Probable Cause |
powerProblem |
|||||||||||
Severity |
Condition |
Text |
Corrective Action |
|||||||||
Major |
Unable to detect Power Supply module (faulty or missing). |
Mediant 3100: |
|
|||||||||
Major (Mediant 3100 Only) |
Power source input is faulty. |
"PS1 input fault" or "PS2 input fault" |
|
|||||||||
Major (Mediant 3100 Only) |
Power output from Power Supply module is faulty. |
"PS1 output fault" or "PS2 output fault" |
|
|||||||||
Cleared |
Power Supply module is functioning. |
- |
- |